International Safety Management (ISM) Code, two generators are running in parallel, Generator Not Stopping on Stop Command
marinersgalaxy.com maritime education

Generator Not Stopping on Stop Command: What Are Your Actions?

Generator Not Stopping on Stop Command: What Are Your Actions? If you are a marine engineer or a crew member on board a ship, you may encounter a situation where the electrical generator does not stop on the stop command. This can be a serious problem that can affect the safety and performance of the ship. In this blog post, we will discuss some possible causes and actions to take when faced with this scenario.

Possible Causes of Generator Not Stopping on Stop Command

There are many factors that can prevent the generator from stopping on the stop command. Some of the common ones are:

– Faulty stop solenoid: The stop solenoid is an electromechanical device that controls the fuel supply to the engine. When the stop command is given, the solenoid should cut off the fuel and stop the engine. However, if the solenoid is defective or stuck, it may not respond to the command and keep supplying fuel to the engine.

– Faulty wiring or connections: The wiring and connections between the control panel and the generator may be damaged or loose, causing a loss of signal or interference. This can prevent the stop command from reaching the generator or cause it to malfunction.

– Faulty governor: The governor is a device that regulates the speed and frequency of the generator. It senses the load and adjusts the fuel supply accordingly. If the governor is faulty, it may not sense the stop command and keep supplying fuel to maintain the speed and frequency.

– Faulty fuel pump or injector: The fuel pump and injector are responsible for delivering fuel to the engine. If they are faulty, they may deliver excess fuel or leak fuel into the engine. This can cause the engine to run even after the stop command is given.

Actions to Take When Generator Does Not Stop on Stop Command

If you encounter a situation where the generator does not stop on the stop command, you should take the following actions:

– Try to stop the generator manually: Most generators have a manual stop lever or button that can be used to override the automatic control system and cut off the fuel supply. You should locate this lever or button and try to stop the generator manually. However, you should be careful not to damage the generator or injure yourself while doing so.

Generator Not Stopping on Stop Command
Copyrights: www.marinersgalaxy,com

– Check the wiring and connections: You should inspect the wiring and connections between the control panel and the generator for any signs of damage or looseness. You should also check for any short circuits or ground faults that may interfere with the signal. If you find any problems, you should try to fix them or call for assistance.
– Check the stop solenoid: You should check if the stop solenoid is working properly by measuring its resistance and voltage. You should also check if it is receiving power and signal from the control panel. If you find any problems, you should try to replace or repair the solenoid or call for assistance.
– Check the governor: You should check if the governor is working properly by observing its movement and response. You should also check if it is receiving power and signal from the control panel. If you find any problems, you should try to adjust or repair the governor or call for assistance.
– Check the fuel pump and injector: You should check if the fuel pump and injector are working properly by measuring their pressure and flow. You should also check if they are leaking fuel into the engine. If you find any problems, you should try to replace or repair them or call for assistance.

Conclusion

A generator that does not stop on the stop command can be a dangerous situation that can affect the safety and performance of the ship. Therefore, you should act quickly and cautiously to identify and resolve the problem. You should also follow proper procedures and safety precautions while dealing with electrical equipment. We hope this blog post has been helpful in providing some information and guidance on this topic.

Ashish S
Hi there! Well I am not a writer, just writes what can help people-that's it. Interested in listening from you. Loves to talk about gadget, music, nerdy stuff and witty substance in the talks. A Good respect in heart- for web.
https://marinersgalaxy.com

Leave a Reply

Your email address will not be published. Required fields are marked *